gc ms spectrometer gc gas chromatography
"
GM6100 고 민감성 가스 염색체 질량 분광 (GC-MS) 시스템
Introduction of Gas Chromatography-Mass Spectrometry (GC-MS) Systems Wayeal GM6100 Gas Chromatography-Mass Spectrometry (GC-MS) Systems integrates the upgraded GC6100 gas chromatograph with a high-performance mass spectrometer detector, creating a precise and intelligent gas chromatography-mass spectromet system. Through advanced control systems and intelligent algorithms, it ensures the continuity and stability of the experimental process. Technical Specification of GM6100
10.1인치 터치 스크린 GC-MS 가스 크로마토그래피 질량 분석기 (EI 이온 소스 포함)
Technical Specifications of GM6100 Gas Chromatography Mass Spectrometer Working Conditions Power Supply 220V ±10%, 50Hz ±2% Ambiet Temperature 5°C to 40°C Relative Humidity 20%~85% GC Injection Port Injection Port Split/Splitless Maximum Operating Temperature 450°C Control Prexision 0.001psi Control Range 0-100psi Maximum Split Ratio 12500:1 Optional Carrier Gases N2, H2, He, Ar Flow Rate Range (with N2 as carrier gas) 0-500mL/min Oven Temperature Range Above ambient
고급 GC-MS 가스 크로마토그래피 질량 분석기 (EI 이온 소스 포함)
Technical Datas of GM6100 GC-MS Working Conditions Power Supply 220V ±10%, 50Hz ±2% Ambiet Temperature 5°C to 40°C Relative Humidity 20%~85% GC Injection Port Injection Port Split/Splitless Maximum Operating Temperature 450°C Control Prexision 0.001psi Control Range 0-100psi Maximum Split Ratio 12500:1 Optional Carrier Gases N2, H2, He, Ar Flow Rate Range (with N2 as carrier gas) 0-500mL/min Oven Temperature Range Above ambient temperature +4°C to 450°C Programmable
OEM FID 가스 색층 분석 기구 GC MS 분광계
Gas Analyzers Chromatography Gas Chromatograph with FID Detectors Product Introduction GC6000 gas chromatography is equipped with FID6000 detector and ASL6000 automatic sampler; it can be equipped with FPD, ECD and other detectors, and it can be equipped with Wanyi self-produced air purification system. Product Characteristics 1. High automation and high efficiency The whole machine realizes computer control; Rich self-diagnosis and alarm functions; Multi-step program
EI 이온 소스 단일 사중극자 질량 분석기 가스 크로마토그래프 질량 분석기
System Instroduction of GM6100 Gas Chromatography Mass Spectrometer From sample injection to data analysis, the Wayeal GM6100 Series delivers a seamless analytical experience. The system integrates the upgraded GC6100 gas chromatograph with the high-performance MSD7000 mass spectrometry detector to form a precise and intelligent GC-MS system. An advanced control system with intelligent algorithms ensures continuity and stability throughout the workflow. With a single
고성능 FID 가스 크로마토그래프 질량 분광계 GC MS 계측기
Wayeal High Performance Gas Chromatography Instrument Machine Price Product Introduction GC6000 gas chromatography instrument is composed of an injector, detector, column, column temperature chamber, separation system and data processing system. Product Parameter Gas Chromatography Instrument Color White+Blue Sample Positions 16 Stationary Phase Solid Adsorbent Mobile Phase Liquid Detector FID Detector Sampler Six-way valve Circuit System 3 Qualitative Repeatability ≤0.05%
GM6100 가스 크로마토그래피 질량 분석기 GCMS, 최대 스캔 속도 20000amu/s
System Introduction of GM6100 Gas Chromatography Mass Spectrometer Integrated System The Wayeal GM6100 Series combines the upgraded GC6100 gas chromatograph with the high-performance MSD7000 mass spectrometry detector to form a precise and intelligent GC-MS system. Intelligent Control An advanced control system with intelligent algorithms ensures continuity and stability throughout the experimental process. Full Automation A single intuitive software interface gives users
실험실 분석용 고민성 가스 염색체 질량 분광기
Technical Parameters of GM6100 GCMS Working Conditions Power Supply 220V ±10%, 50Hz ±2% Ambiet Temperature 5°C to 40°C Relative Humidity 20%~85% GC Injection Port Injection Port Split/Splitless Maximum Operating Temperature 450°C Control Prexision 0.001psi Control Range 0-100psi Maximum Split Ratio 12500:1 Optional Carrier Gases N2, H2, He, Ar Flow Rate Range (with N2 as carrier gas) 0-500mL/min Oven Temperature Range Above ambient temperature +4°C to 450°C Programmable
CE 인증 GM6100 가스 크로마토그래피-질량 분석기 GCMS
Technical Parameters of GM6100 Working Conditions Power Supply 220V ±10%, 50Hz ±2% Ambiet Temperature 5°C to 40°C Relative Humidity 20%~85% GC Injection Port Injection Port Split/Splitless Maximum Operating Temperature 450°C Control Prexision 0.001psi Control Range 0-100psi Maximum Split Ratio 12500:1 Optional Carrier Gases N2, H2, He, Ar Flow Rate Range (with N2 as carrier gas) 0-500mL/min Oven Temperature Range Above ambient temperature +4°C to 450°C Programmable Temperatur